Manhole cover - Frame fitting

Foul and surface water, private drains and public sewers, land drains and soakaways, filter drains and any other ways of getting rid of water.
Post Reply
franky
Posts: 12
Joined: Wed Mar 05, 2014 11:15 am
Location: north yorks

Post: # 111098Post franky

fitting replacement ductile iron frame, it overhangs chamber by approx 5 mm on inner edge on each long side but well onto brick top and bottom - is this acceptable - height is good
franky

dig dug dan
Posts: 2504
Joined: Thu Jul 10, 2003 10:20 pm
Location: hemel hempstead,herts. 01442 212315

Post: # 111102Post dig dug dan

Fine for domestic foot traffic, not so for vehicles
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"

franky
Posts: 12
Joined: Wed Mar 05, 2014 11:15 am
Location: north yorks

Post: # 111106Post franky

thank you - will shift top course over 15 mm then fit frame when cured - is there anything special to bear in mind when doing this
franky

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 111107Post seanandruby

How deep is the bed goig to be? If it's to deep you'll need to regulate the brickwork, aim for 10/15ml. Id' use building sand and cement 3/1 mix. Bed it on straight away and tap down to height.
sean

franky
Posts: 12
Joined: Wed Mar 05, 2014 11:15 am
Location: north yorks

Post: # 111108Post franky

thank you - have now regulated brickwork and bed is 15mm - in for a cuppa - will use mix you suggest with a dollop of SBR
franky