Speedfit plumbing connections

General banter, tradesmen, recommendations and warnings, surplus materials, humour and owt else!
michaelthegardener
Posts: 638
Joined: Sat Jul 17, 2010 8:20 am
Location: bristol

Post: # 87303Post michaelthegardener

replaceing my kitchen at the mo and my plumbing isnt the best are push fit connections really as good as they seam ? :D

Dave_L
Site Admin
Posts: 4732
Joined: Fri Jul 28, 2006 8:47 pm
Location: Somerset
Contact:

Post: # 87304Post Dave_L

Pretty much so, yes. Not my cup of tea, I like a nice mechanical soldered joint, myself.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset

See what we get up to Our Facebook page

dig dug dan
Posts: 2504
Joined: Thu Jul 10, 2003 10:20 pm
Location: hemel hempstead,herts. 01442 212315

Post: # 87309Post dig dug dan

My mate and I spent a whole day trying to solder a pipe join under his sink, but it wouldnt work as we couldnt fully shut off the water. Brought a push fit, job done in minutes. Much simpler michael!
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 87312Post lutonlagerlout

they work well for water
make sure any existing pipes are clean i.e. no paint
also do not use on a pressurised system
someone i know very well did this as a favour and flooded the whole downstairs of a police officers house
someone very close to me now :(
no more plumbing for me
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

darrenba
Posts: 77
Joined: Sat Jul 05, 2008 6:47 pm
Location: Dorset, UK
Contact:

Post: # 87313Post darrenba

If you're using the plastic pipe too make sure you don't forget the inserts.

michaelthegardener
Posts: 638
Joined: Sat Jul 17, 2010 8:20 am
Location: bristol

Post: # 87316Post michaelthegardener

i only want to use them for the sink ive got to move it a foot or so the ones ive seen in screwfix say they can be used on a pressurised system .....

bodgeitandscarper
Posts: 345
Joined: Tue Aug 07, 2007 9:23 pm
Location: Hereford

Post: # 87318Post bodgeitandscarper

Hep20 is a good make to use, the fittings seem better quality than the Speedfit.
Maintenance Man

Dave_L
Site Admin
Posts: 4732
Joined: Fri Jul 28, 2006 8:47 pm
Location: Somerset
Contact:

Post: # 87319Post Dave_L

John Guest is reccomended too.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset

See what we get up to Our Facebook page

henpecked
Posts: 1328
Joined: Thu Mar 26, 2009 9:00 am
Location: Warwickshire
Contact:

Post: # 87321Post henpecked

michaelthegardener wrote:i only want to use them for the sink ive got to move it a foot or so the ones ive seen in screwfix say they can be used on a pressurised system .....
Its usually tested to 10 bar but water runs on a 3 bar system, so it will be a pressurised system to some extent. I think LLL means an underfloor heating affair.

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 87323Post lutonlagerlout

no i mean pressurised like as in a combi boiler
I can vouch that a stop end i put on (doing a favour because the plumber never showed) popped off during the night
I'd be happy with them on hot and cold water feeds,just not on the heating loop
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

henpecked
Posts: 1328
Joined: Thu Mar 26, 2009 9:00 am
Location: Warwickshire
Contact:

Post: # 87324Post henpecked

lutonlagerlout wrote:no i mean pressurised like as in a combi boiler
I can vouch that a stop end i put on (doing a favour because the plumber never showed) popped off during the night
I'd be happy with them on hot and cold water feeds,just not on the heating loop
LLL
Ive got a couple of stop ends on my combi system, was for a towel rail I never put in..............4 years ago :;):
The combi system only pressurised to 2 bar at best. What you have to remember with speed fit, is to pull out the little gadget on the end and once engaged, give the pipe a yank backwards. This is why they pressurise it to 10 bar when testing, firstly it gives the joints a good thorough testing and secondly, it pulls the pipes snug.

Bob_A
Posts: 861
Joined: Wed Feb 27, 2008 9:30 pm
Location: SE London/ NW Kent

Post: # 87325Post Bob_A

I've used Hep2o without any problem.
Just don't stick you finger down a coupling or you may never get it back out!

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 87328Post lutonlagerlout

sorry i should have clarified
i mean onto old existing painted copper pipes
it failed on me in less than 12 hours
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

local patios and driveway
Posts: 1568
Joined: Mon May 10, 2010 9:58 pm
Location: Gatwick
Contact:

Post: # 87330Post local patios and driveway

In my last house i had two push fit joints fail and cause flooding. If you lose pressure behind the fitting they can simply come lose as they are held toght by the water pressure. In my mind its just as easy to to use yorkshire fittings and do the job properly. A little bit of youtube study will teach you all you need to know how to solder.

rimexboy
Posts: 916
Joined: Thu Aug 07, 2008 8:31 pm

Post: # 87339Post rimexboy

speed fit are fine ive used them befor no probas at all, but as said if going onto old pipe make sure the old pipe is nice and clean and as already said dont forget the inserts inside the plastic pipe, easy to do and simple for someone like me lol

ps dont forget to put an isolation vaulve in too you may need to isolate one tap at some point in the future...