Speedfit plumbing connections
-
- Posts: 638
- Joined: Sat Jul 17, 2010 8:20 am
- Location: bristol
-
- Site Admin
- Posts: 4732
- Joined: Fri Jul 28, 2006 8:47 pm
- Location: Somerset
- Contact:
Pretty much so, yes. Not my cup of tea, I like a nice mechanical soldered joint, myself.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset
See what we get up to Our Facebook page
See what we get up to Our Facebook page
-
- Posts: 2504
- Joined: Thu Jul 10, 2003 10:20 pm
- Location: hemel hempstead,herts. 01442 212315
My mate and I spent a whole day trying to solder a pipe join under his sink, but it wouldnt work as we couldnt fully shut off the water. Brought a push fit, job done in minutes. Much simpler michael!
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
-
- Posts: 77
- Joined: Sat Jul 05, 2008 6:47 pm
- Location: Dorset, UK
- Contact:
-
- Posts: 638
- Joined: Sat Jul 17, 2010 8:20 am
- Location: bristol
-
- Posts: 345
- Joined: Tue Aug 07, 2007 9:23 pm
- Location: Hereford
-
- Site Admin
- Posts: 4732
- Joined: Fri Jul 28, 2006 8:47 pm
- Location: Somerset
- Contact:
John Guest is reccomended too.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset
See what we get up to Our Facebook page
See what we get up to Our Facebook page
-
- Posts: 1328
- Joined: Thu Mar 26, 2009 9:00 am
- Location: Warwickshire
- Contact:
Its usually tested to 10 bar but water runs on a 3 bar system, so it will be a pressurised system to some extent. I think LLL means an underfloor heating affair.michaelthegardener wrote:i only want to use them for the sink ive got to move it a foot or so the ones ive seen in screwfix say they can be used on a pressurised system .....
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
-
- Posts: 1328
- Joined: Thu Mar 26, 2009 9:00 am
- Location: Warwickshire
- Contact:
Ive got a couple of stop ends on my combi system, was for a towel rail I never put in..............4 years ago :;):lutonlagerlout wrote:no i mean pressurised like as in a combi boiler
I can vouch that a stop end i put on (doing a favour because the plumber never showed) popped off during the night
I'd be happy with them on hot and cold water feeds,just not on the heating loop
LLL
The combi system only pressurised to 2 bar at best. What you have to remember with speed fit, is to pull out the little gadget on the end and once engaged, give the pipe a yank backwards. This is why they pressurise it to 10 bar when testing, firstly it gives the joints a good thorough testing and secondly, it pulls the pipes snug.
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
-
- Posts: 1568
- Joined: Mon May 10, 2010 9:58 pm
- Location: Gatwick
- Contact:
In my last house i had two push fit joints fail and cause flooding. If you lose pressure behind the fitting they can simply come lose as they are held toght by the water pressure. In my mind its just as easy to to use yorkshire fittings and do the job properly. A little bit of youtube study will teach you all you need to know how to solder.
-
- Posts: 916
- Joined: Thu Aug 07, 2008 8:31 pm
speed fit are fine ive used them befor no probas at all, but as said if going onto old pipe make sure the old pipe is nice and clean and as already said dont forget the inserts inside the plastic pipe, easy to do and simple for someone like me lol
ps dont forget to put an isolation vaulve in too you may need to isolate one tap at some point in the future...
ps dont forget to put an isolation vaulve in too you may need to isolate one tap at some point in the future...