Sleepers retaining wall
-
- Posts: 103
- Joined: Fri Mar 12, 2010 4:28 pm
- Location: Birmingham
Hello all,
I want to build a retaining wall of sleepers, only a small one, perhaps 500 high, so sleepers are laid lengthways giving 200mm thickness.
What's the best way to bed them down whilst securing them all together AND into the ground to stop them moving?
Behind them will be a patio of 2x2s edged in a soldier course of bricks.
Thanks a lot.
I want to build a retaining wall of sleepers, only a small one, perhaps 500 high, so sleepers are laid lengthways giving 200mm thickness.
What's the best way to bed them down whilst securing them all together AND into the ground to stop them moving?
Behind them will be a patio of 2x2s edged in a soldier course of bricks.
Thanks a lot.
-
- Posts: 196
- Joined: Fri Jun 17, 2011 10:49 pm
- Location: Romford Essex
-
- Posts: 103
- Joined: Fri Mar 12, 2010 4:28 pm
- Location: Birmingham
I wasn't planning on having them all stood on end like that but rather lying down, building a wall as you would with bricks. As you have pictured would probably be easier as i can bury them into ground individually and concrete them in.
My thinking so far is to drive rebar through at least the lower sleeper into the ground. i can then screw each sleeper on top in turn. I obviously don't want the wall to move and have the paving behind it to start falling away at its edge.
My thinking so far is to drive rebar through at least the lower sleeper into the ground. i can then screw each sleeper on top in turn. I obviously don't want the wall to move and have the paving behind it to start falling away at its edge.
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
-
- Posts: 1990
- Joined: Sun Mar 25, 2007 10:49 pm
- Location: N/Ireland
Here's how I do it.
I'm not fussed on the strength of your method long term I find relying to much on the fixings instead on the woods natural strength usually leads to failure. I place the upright sleeper on the outside that way it's not in the soil and the fixing is just to keep it in place and nothing else. It's best to line the whole thing with plastic so no wood is in contact with the soil underneath or behind. This way is not only much stronger than your way but also very cheap I don't see the point in laying them flat unless it's for design reasons. The posts are at least 650mm into the ground on the higher parts and about 300mm on the lower parts.
I'm not fussed on the strength of your method long term I find relying to much on the fixings instead on the woods natural strength usually leads to failure. I place the upright sleeper on the outside that way it's not in the soil and the fixing is just to keep it in place and nothing else. It's best to line the whole thing with plastic so no wood is in contact with the soil underneath or behind. This way is not only much stronger than your way but also very cheap I don't see the point in laying them flat unless it's for design reasons. The posts are at least 650mm into the ground on the higher parts and about 300mm on the lower parts.
Can't see it from my house
-
- Posts: 2504
- Joined: Thu Jul 10, 2003 10:20 pm
- Location: hemel hempstead,herts. 01442 212315
i cant help thinking mr. pink,that yours are not far enough in the ground ???
when we do slab retainers the council want at least 30 % below ground level
then haunching up that
i agree. thats no where near enough in the ground. epic fail on that i'm afraid
You can indeed buy special screws called timberloks. About 200mm long, screw in with a bit adaptor that comes with the screws
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
-
- Posts: 2504
- Joined: Thu Jul 10, 2003 10:20 pm
- Location: hemel hempstead,herts. 01442 212315
apologies. posted before your reply.
if you are digging them in, thats fine.
We generally concrete 4x4 posts BEHIND the wall, and screw through. The idea of lying them flat is strength.
many times i have laid a crushed concrete base, consolidated to levels, and laid the sleepers flat (new ones) on top, with the posts behind
i personally don't like to see the posts in front, it doesn't look right, and from your picture, gives an awkward mowing hazard
if you are digging them in, thats fine.
We generally concrete 4x4 posts BEHIND the wall, and screw through. The idea of lying them flat is strength.
many times i have laid a crushed concrete base, consolidated to levels, and laid the sleepers flat (new ones) on top, with the posts behind
i personally don't like to see the posts in front, it doesn't look right, and from your picture, gives an awkward mowing hazard
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
-
- Posts: 1990
- Joined: Sun Mar 25, 2007 10:49 pm
- Location: N/Ireland
If the sleepers are in the lawn then we would put a mowing strip in front of them so there's no tricky corners but I never lay and haunch softwood sleepers on concrete because they'll rot in no time. One of the gardens I'm refurbing at the moment has a .6m wall built just like that and it's turned to mush after only 7 years and thats just one of many I've seen fail over the years. Timberlocks and 4x4 wood are fine for planters and very low stuff but totally useless on something that you expect to hold back tons of soil for the next 20 years. If you are fixing from the back then at the very least you need to use bolts and wide washers the thread on those srcews is only 1 1/2 inches long as soon as the wood softens it starts to pull out. A lot of folk assume the treated softwood is as durable as the oak but in reality it's crap and needs belt and braces protection to make it last.
Can't see it from my house
-
- Posts: 2504
- Joined: Thu Jul 10, 2003 10:20 pm
- Location: hemel hempstead,herts. 01442 212315
thats true, but you need a very long drill bit, and some very long bolts!
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"
-
- Posts: 103
- Joined: Fri Mar 12, 2010 4:28 pm
- Location: Birmingham
So ideally I need to keep softwood sleepers away from contact with soil. Does that mean poly sheet behind the sleepers or should i perhaps fill in immediately behind them with pea shingle so there's no water retention ?
If i bed and haunch in concrete will that not mean that a soaked sleeper would struggle to dry out being surrounded by concrete?
Maybe i should pay extra and go for oak. I don't like the sound of the 7 years life expectancy of softwood sleepers.
If i bed and haunch in concrete will that not mean that a soaked sleeper would struggle to dry out being surrounded by concrete?
Maybe i should pay extra and go for oak. I don't like the sound of the 7 years life expectancy of softwood sleepers.
-
- Posts: 661
- Joined: Mon Feb 21, 2005 11:54 am
- Location: Birmingham, west midlands, UK
- Contact:
I agree with Pablo, we never bed or haunch Sleepers, no point, and we always set the posts to the front if it's a retaining feature, but hide them if it's a low feature such as a planter etc
If your worried about there lifespan, give them a few coats of another preservative before you install them, something like Creosote substitute, or a water seal, then line them as described. The softwood sleepers will last you just have to reduce the amount of moisture they are absorbing. I've seen hardwood walls rot nearly as fast as softwoods, because there application has been wrong.
If your worried about there lifespan, give them a few coats of another preservative before you install them, something like Creosote substitute, or a water seal, then line them as described. The softwood sleepers will last you just have to reduce the amount of moisture they are absorbing. I've seen hardwood walls rot nearly as fast as softwoods, because there application has been wrong.
Gi it sum ommer
-
- Site Admin
- Posts: 4420
- Joined: Sat Aug 09, 2008 3:55 pm
- Location: high peak
- Contact:
Only one I did in new French oak which where ridiculous hard we laid as the op is planning, poured a concrete footing sat them on and fixed to 4x4 post behind and returned the sides to make like a tank in placement then geotextiled and french drain behind them. All fastened with timber lock driven with a big Hilti as the oak was so tough
See railwaysleepers.co.uk where I got them from and a wealth of past projects there to look at, mr pink you need min 33% for counter leaverd strength well that what our engineer says for sheet piling
See railwaysleepers.co.uk where I got them from and a wealth of past projects there to look at, mr pink you need min 33% for counter leaverd strength well that what our engineer says for sheet piling
Giles
Groundworks and Equestrian specialists, prestige new builds and sports pitches. High Peak, Cheshire, South Yorkshire area.
http://www.gbgroundworks.com
Groundworks and Equestrian specialists, prestige new builds and sports pitches. High Peak, Cheshire, South Yorkshire area.
http://www.gbgroundworks.com