Floor screed advise please

Other groundworks tasks, such as roads and footpaths, terracing, fencing, foundations, walls and brickwork, tools and plant.
loudog
Posts: 214
Joined: Wed Jan 02, 2008 12:59 pm
Location: mells

Post: # 72117Post loudog

Hi ya all, My game is block paving and tarmac but build the odd wall and lay foundations. I built a concrete floor which he has built the block work on but he wants me to come back and do the floor screed for him. It is not a big area about 4mts x4mts, any advise would be really good. I am familiar with screed rails and know the mix has to be dryish, do I need to add any liquids to the mix?

Kind regards chaps

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 72122Post lutonlagerlout

grit sand/ cement 3:1 +100 ml of pva and a handful of fibres
set your screed rails up to the levels then infill and screed off
if you arent really a a screeder (like me) go back the next day and remove the rails and infill the voids
in a normal mixer about a 1 /5 bucket of clean water
cheers LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

loudog
Posts: 214
Joined: Wed Jan 02, 2008 12:59 pm
Location: mells

Post: # 72124Post loudog

Thanks LLL, my friend has put me off as he said it is a skilled job, but been paving for good 10years and can concrete, have a good understanding of screeding. Do i need to wet the existing concrete floor as not to draw the cement out of the floor screed.
Thanks

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 72125Post lutonlagerlout

sorry mate,yes you need to prime the floor with a pva and water mix
its by no means hard,you will just be slower than pro screeders
the gear mustn't be too wet
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

henpecked
Posts: 1328
Joined: Thu Mar 26, 2009 9:00 am
Location: Warwickshire
Contact:

Post: # 72128Post henpecked

I'd say screeding is more forgiving then concrete finishing TBH

rab1
Posts: 1869
Joined: Sun Jun 07, 2009 10:19 pm
Location: scotland

Post: # 72153Post rab1

the mix has to be dry as in when squashed in your hand forms a ball but your hands are still dry.
God loves a tryer

macgrl
Posts: 27
Joined: Tue Feb 15, 2011 11:13 am
Location: coventry

Post: # 73046Post macgrl

Hello all,

I too am laying some screed. I have no experience of this but the area is quite small and will be under a bath. I took the old one out to find that the floor level is about 40mm lower than the rest of the bathroom floor.

Its is the contrete house base layer below it. The area is the size of a regular bath so not very big and won't be seen.

So basically do I mix 3:1 grit sand to cement with 100ml of pva to a dry mix that can be compressed in my hands. I shouldn't have a problem getting it level with rails etc.

Do I have to add fibres or doesn't it matter as it is under the bath and won't have any foot traffic on it?

I will need to seal the contrete floor with a pva / water mix - what ratios.

Thank you very much.

macgrl

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 73047Post lutonlagerlout

it should tell you on the PVA/SBR the ratio for priming
for me half a bucket of water and maybe 250ml works ok

just take your time and keep it moist rather than wet
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

macgrl
Posts: 27
Joined: Tue Feb 15, 2011 11:13 am
Location: coventry

Post: # 73050Post macgrl

Thank you very much lutonlager lout.

Two other quick questions -

do i really need fibres? - I can't seem to find them anywhere to buy. are they really that important considering the job I am doing.

Also I have had a look around and would a 3:1 mix be too strong? could i use 4/5:1

Thanks so much. Very much appreciated.

macgrl

Pablo
Posts: 1990
Joined: Sun Mar 25, 2007 10:49 pm
Location: N/Ireland

Post: # 73052Post Pablo

No you don't need fibre and 5:1 will be fine.
Can't see it from my house

macgrl
Posts: 27
Joined: Tue Feb 15, 2011 11:13 am
Location: coventry

Post: # 73058Post macgrl

Thank you very Much pablo

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 73061Post lutonlagerlout

all floor screed should be 3:1
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

Brucieboy
Posts: 162
Joined: Sun Jul 17, 2011 1:21 am
Location: Essex

Post: # 73080Post Brucieboy

LLL, have to disagree. We supply 1000's of cubic metres of ready mixed floor screed every year, the vast majority of which is 4:1. Fibrescreed is increasing in popularity, mainly for use with underfloor heating systems. We are rarely asked for 3:1 - it's too rich!! All our screed is mixed in forced action mixers.

Macgrl - be careful to ensure the screed is fully dry before applying resilient floor coverings such as vinyl, particulary the very expensive stuff such as Amtico. The rule of thumb is 1 day per 1mm thickness but considerably longer if the screed is placed directly onto a concrete slab without a separating membrane between. Failure to do so could result in the vinyl bubbling and lifting due to vapour pressure. Other finishings such as carpet are not so critical.
Retired DIY'er

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 73081Post lutonlagerlout

have you got a link or reference for that brucie?
not doubting you ,but I have always been told to knock up floor screed at 3:1
the more cement the harder it is to screed but IME a far better job
the guys i use with the putzmeister use around 8 bags of cement to 1 tonne of grit sand,however this sand has an inherent moisture content,so maybe that is more like 4:1 too
LLL :)
"what,you want paying today??"

YOUR TEXT GOES HERE

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 73083Post lutonlagerlout

found this on cemex site

Product reference: Readyscreed Original

Mix:
1:3 - For minimum strength of 25N/mm2 after 3 days and 30N/mm2 after 28 days
1:4 - For minimum strength of 20N/mm2 after 3 days and 20N/mm2 after 28 days

LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

Post Reply