Hello 1st time on the board, can i ask two questions.
1) What’s the difference between a Manhole Cover and a Inspection Chamber, Is it just the size.
2) The bottom of my manhole/IC?, where it meets the clay bit "Half round pipe", has disappeared. Is it okay to repoint this, with ordinary mortar and a waterproffer?
What does Tony recomend?
Manhole - Manhole inspection chamber pointing
-
- Posts: 17
- Joined: Sun Feb 27, 2005 2:53 pm
- Location: North Yorkshire
-
- Site Admin
- Posts: 8346
- Joined: Mon Jul 05, 2004 7:27 pm
- Location: Warrington, People's Republic of South Lancashire
- Contact:
The diff between a Manhole (with or without a cover) and an IC is, primarily one of size. A maintenance operative should be able to climb down into a manhole, whereas an Inspection Chamber is purely for inspection from surface level and you;re not supposed to be able to get into it.
Depth to invert and pipe bore determines whether a MH or IC is required.
And for your bonus question....
Do you mean the benching has disappeared? If so, it could be repaired with a high-strength mortar, beefed up with some SBR or Ronafix, but a granolithic mortar is preferred as it's less liable to abrasion. It needs to be a 3:1 mix.
Depth to invert and pipe bore determines whether a MH or IC is required.
And for your bonus question....
Do you mean the benching has disappeared? If so, it could be repaired with a high-strength mortar, beefed up with some SBR or Ronafix, but a granolithic mortar is preferred as it's less liable to abrasion. It needs to be a 3:1 mix.