when building raised beds and retaining walls I have been using 4" thick posts concreted into the ground to attach the sleepers to using 6 inch countersunk screws, they seem really solid when done but I'm concerned about the posts rotting !
what measures can I take to prevent this in years to come ?
Sleepers - Raised beds and retaining walls
-
- Posts: 77
- Joined: Sat Jul 05, 2008 6:47 pm
- Location: Dorset, UK
- Contact:
-
- Posts: 1568
- Joined: Mon May 10, 2010 9:58 pm
- Location: Gatwick
- Contact:
-
- Posts: 1568
- Joined: Mon May 10, 2010 9:58 pm
- Location: Gatwick
- Contact:
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
i spoke at length to a structural engineer about "timber retaining walls"
the main points to consider are
1 height over 1 m it should really be designed
2 drainage,a land drain and weepholes are a must on retaining structures,its the build up of water that causes most to fail
3 any post should be at least 600mm into the ground and also potentially anchored at the rear
4 old railway sleepers are apparently very strong,new softwood timber much less so,I had a 3by 3 post supporting a tree in my garden and it rotted through after 5 years
LLL
the main points to consider are
1 height over 1 m it should really be designed
2 drainage,a land drain and weepholes are a must on retaining structures,its the build up of water that causes most to fail
3 any post should be at least 600mm into the ground and also potentially anchored at the rear
4 old railway sleepers are apparently very strong,new softwood timber much less so,I had a 3by 3 post supporting a tree in my garden and it rotted through after 5 years
LLL
-