Pad stone on a sunday

General banter, tradesmen, recommendations and warnings, surplus materials, humour and owt else!
jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64058Post jonnyboyentire

Due to lets call it a balls up, I have a steel on a genie right now waiting for a padstone underneath it. It's to bed 110mm above a perp.steel so I'd prefer a padstone to cut down ideally. The genie goes back on Tuesday at 7am, no option.

Anyone know who will do a pad stone on a Sunday/BH Monday? Or have any alternative suggestions - not keen on engineers+big bed+slate etc.
full bed only - spot and dabs are the scourge!!

henpecked
Posts: 1328
Joined: Thu Mar 26, 2009 9:00 am
Location: Warwickshire
Contact:

Post: # 64063Post henpecked

Solid blues have a compaction ration of 60 newtons, if your really stuck that is.
I always thought a kerb had the same concrete as padstones? I might be wrong, but try and chop one up if it is.

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 64071Post lutonlagerlout

johnny if the steel is in the correct location then the existing must be cut down to make the pad work regardless
lately we have been using 140by 100 by 600 mm prestressed concrete lintels as pads
but, big BUT, you must do as per the engineers drawings
i do have a couple of the above lintels in my lock up if you want to drive to luton
IME 110mm isnt enough for A padstone
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64098Post jonnyboyentire

ok what I have is a 5.1m steel at 2.1m from dpc over the bifolds. The steel in question takes the floor joists ands a 4" blockwork wall above, bears on the top of this one at a right angle but 110mm higher, supported at the other end with a pier as per the drawing. So i need something betwen the steels if you see what I mean.
full bed only - spot and dabs are the scourge!!

jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64185Post jonnyboyentire

All sorted.
Thanks for the offer LLL, used your advice and went for a concrete lintel.
Onwards and hopefully upwards ;)

Image

Image
full bed only - spot and dabs are the scourge!!

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 64191Post lutonlagerlout

could the perp steel not have sat directly on the other steel or was that too low?
i would have been tempted to raise the lower steel and stud down to the bi=-folds
steels could then be welded
i take it the underground pipe is temp. johhny?
:;):
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64195Post jonnyboyentire

As you say Tony, too low. Was tempted to stud it too but wanted to do it as per the drawing as far as we could (drawing showed a Celcon in between the steels, I was not exactly keen on that idea, i do prefer to overengineer things lol.
That's a dressing-room-in-waiting that's piped up, so yes, its temp!

Am a bit of an amateur at this so permanently ****ting myself as well as trying to get back to my own business....

All help gratefully received with thanks!
full bed only - spot and dabs are the scourge!!

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 64197Post lutonlagerlout

just 2 things i noticed as well

1 are they celcon blocks?
we dont use them anymore as they are not worth a carrot when the plaster gets on them,cracks galore
2 why is the oversite 150mm below DPC?
underfloor heating?
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64198Post jonnyboyentire

They are celcon's, what do you use now Tony?
Yes, ufh (hopefully, budget clawback allowing....)
full bed only - spot and dabs are the scourge!!

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 64199Post lutonlagerlout

we use aglites of fibolites,all those thermalite/celcon type blocks seem to suffer from lack of adhesion and cracking
I think if you dry line them you may be ok
we used them for a while due to their lightness but not anymore
cheers LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64219Post jonnyboyentire

damn.
Cheers though LLL I will look into the alternatives asap. We are at ff joist height so could change for the upstairs at least.
Interestingly on the flank wall, 14m single storey, I have a plate to dpc vertical crack on both inner and outer leaves, about 2m apart. Through joints and blocks. My neighbour is a surveyor, reckons its down to thermal changes as the blockwork is in full sun, and was laid in Jan, we've had nothing but sun since.
full bed only - spot and dabs are the scourge!!

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 64220Post lutonlagerlout

14m with no expansion joint?
oh dear,architect wants a kick up the arris
you dont get any cracking with fibolites or aglites,bit heavier to lay but much better blocks
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64228Post jonnyboyentire

I did wonder at the time the (now departed) builder laid them about expansion.
There's no way I can add that now is there?
full bed only - spot and dabs are the scourge!!

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 64230Post lutonlagerlout

you can cut it out with a grinder
and then add a foam strip to the joint
internally try and get the joint in a corner as you need to have 2 stop beads abutting each other on the plaster
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

jonnyboyentire
Posts: 320
Joined: Tue May 27, 2008 7:09 pm
Location: uk

Post: # 64233Post jonnyboyentire

ooo i like that idea.
Have a cpl of internal 4" divinding walls to go in so will take the opportunity. Cheers LLL
I was in Allbuild today and the lad suggested the crack could be notched with a 4" grinder then chemical-fixing stuff gunged in so thats on the list for this week.
Trying to organise the tarp for the temp roof arrangement, bl**dy massive it is, about 12m2. Fella in Farnham does them apparently.
full bed only - spot and dabs are the scourge!!

Post Reply