Questions

Foul and surface water, private drains and public sewers, land drains and soakaways, filter drains and any other ways of getting rid of water.
Post Reply
GB_Groundworks
Site Admin
Posts: 4420
Joined: Sat Aug 09, 2008 3:55 pm
Location: high peak
Contact:

Post: # 58038Post GB_Groundworks

Image

excuse the ipad sketch, get funny looks groundworker quoting on his ipad haha :)

so i need to put a new gully in where the green circle is to take the sink and washing machine waste which is currently going wronly into the top water which has been cut and blocked about 10 metres from their boundary in the rd

so doing it properly running it rd into the foul in the block paved patio, questions.

best way to connect the 110mm plastic into the salt glaze, to do it properly means an ic so what 2 ad4000 rubber addapters then 330 plastic swept T ic and bring it up into the block paving?

or other ideas? anyway know of any ic that fit salt glaze that take 110mm plastic from the gully




Edited By GB_Groundworks on 1294871341
Giles

Groundworks and Equestrian specialists, prestige new builds and sports pitches. High Peak, Cheshire, South Yorkshire area.

http://www.gbgroundworks.com

msh paving
Site Admin
Posts: 1854
Joined: Tue Aug 19, 2008 7:03 pm
Location: kings lynn norfolk
Contact:

Post: # 58041Post msh paving

hepworth manhole take supersleave pipe and plasic pipe, but supersleave is smaller dia. than regular salt glaze
i would stick to using AC4000 as you know it will work with no messing MSH :)
paving, mini-crusher, mini-digger hire and groundwork
http://mshpaving.co.uk

flowjoe
Posts: 1136
Joined: Sun May 08, 2005 9:25 am
Location: North West

Post: # 58072Post flowjoe

Can you not just install a roddable gully and or fit rodding point ?
http://draindomain.com

Many paths can lead to riches, few in sunlight, some in ditches

GB_Groundworks
Site Admin
Posts: 4420
Joined: Sat Aug 09, 2008 3:55 pm
Location: high peak
Contact:

Post: # 58075Post GB_Groundworks

Rather than the ic? Thought you had to have ic on 90 degree change of direction? I'm going to have to put all the green pipe work in and join it to the salt glaze?
Giles

Groundworks and Equestrian specialists, prestige new builds and sports pitches. High Peak, Cheshire, South Yorkshire area.

http://www.gbgroundworks.com

flowjoe
Posts: 1136
Joined: Sun May 08, 2005 9:25 am
Location: North West

Post: # 58077Post flowjoe

Thought the green circle was a gully ? not a manhole ?

Can you put a roddable gully on the corner and run to a blind junction onto the VC (doing away with the 90 degree bend). or put a roddable gully where the sink is, run that to a junction on the corner (with rodding access upstream of the junction) and run that to a blind junction on the VC ?. :)
http://draindomain.com

Many paths can lead to riches, few in sunlight, some in ditches

GB_Groundworks
Site Admin
Posts: 4420
Joined: Sat Aug 09, 2008 3:55 pm
Location: high peak
Contact:

Post: # 58079Post GB_Groundworks

Yeah that what I was thinking can I do a blind swept junction onto the vitrous clay or does that have to be accessible, I think not as you can rod from gully and from the existing man hole.

What's the best way to join onto the vc Paul?
Giles

Groundworks and Equestrian specialists, prestige new builds and sports pitches. High Peak, Cheshire, South Yorkshire area.

http://www.gbgroundworks.com

Post Reply