Dpc regarding steps - Am i compromising the dpc?

Setts and cobbles, tarmac, asphalt, resin systems, concrete whether it's plain, patterned or stencilled, gravels, etc.
Post Reply
Gray646
Posts: 9
Joined: Sun Mar 28, 2010 11:54 am
Location: Maidenhead

Post: # 47569Post Gray646

Hi,

When building steps in the past, I've not had a problem that the step itself breaches the 150mm rule with regards to the DPC because it's only occuring over a short distance but now I'm looking at a job where the step spans almost the entire length of the back wall due to it being for large sliding patio doors.

Am I still okay to breach the rule for this length? - the step would be coming out about 600mm if that makes any difference.

Replies very much appreciated,

Many thanks,
Graham
You need one of those suction hammers.

irishpaving
Posts: 420
Joined: Mon Jun 29, 2009 11:14 pm
Location: uk

Post: # 47570Post irishpaving

How close are the steps to the dpc.
"I'm spending a year dead for tax reasons."

irishpaving
Posts: 420
Joined: Mon Jun 29, 2009 11:14 pm
Location: uk

Post: # 47586Post irishpaving

Maybe go for a slot drain to run in the step against the wall. Your asking for trouble if you run level or even near it with blocks etc.
"I'm spending a year dead for tax reasons."

Gray646
Posts: 9
Joined: Sun Mar 28, 2010 11:54 am
Location: Maidenhead

Post: # 47593Post Gray646

Well when I looked at the job it wasn't obvious where the dpc was - i.e couldn't see any air bricks or dpc roll poking out - but I'm assuming that the step to be a comfortable height for people will inevitably be above/level with the dpc.

So if I run a slot drain, could I just have it run out into a little hollowed out bit within the step - kind of like a mini soakawayafter all it's not going to be having loads of water going down?

Also could I acheive the same effect as the slot drain by having a gravel strip - say 100mm wide between the house and step?

Cheers
You need one of those suction hammers.

cookiewales
Posts: 1270
Joined: Mon Aug 10, 2009 8:30 am
Location: york work anywhere where the stone takes me
Contact:

Post: # 47595Post cookiewales

Gray646 wrote:Well when I looked at the job it wasn't obvious where the dpc was - i.e couldn't see any air bricks or dpc roll poking out - but I'm assuming that the step to be a comfortable height for people will inevitably be above/level with the dpc.

So if I run a slot drain, could I just have it run out into a little hollowed out bit within the step - kind of like a mini soakawayafter all it's not going to be having loads of water going down?

Also could I acheive the same effect as the slot drain by having a gravel strip - say 100mm wide between the house and step?

Cheers

install some dpc up against wall make sure there is a fall away from house ie 20mm then you will be fine have been doing this for thirty years plus with no comebacks a step is a feature on its own no need to complicate cheers cookie :;):
Originalstonepaving.com

The very best in natural stone paving in new and reclaimed materials
M: 07968 582231

Mikey_C
Posts: 952
Joined: Mon Oct 30, 2006 8:24 pm
Location: Bournemouth, Dorset

Post: # 47616Post Mikey_C

i have heard of some putting code 4 lead against the wall aswell as dpc or dpm, obviously if you hadn't seen this coming code 4 lead will put a dent/destroy any profit!

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 47623Post seanandruby

I would'nt overcomplicate it. Just leave a gap with some fibre board, or the stuff brickies use for movement joints, rebate the top 20ml temporarily. once you've finished take out the rebate and fill with a rubberised sealant. any breaching of air bricks can be extended to the outer risers.
sean

Gray646
Posts: 9
Joined: Sun Mar 28, 2010 11:54 am
Location: Maidenhead

Post: # 47680Post Gray646

Ta very much for all replies. I think I'm going to go with a combination of angling the step a bit more than usual, having some dpc run up against the wall and also a shingle against the house sat in a gully that I'll angle away from the house.

Cheers chaps.
You need one of those suction hammers.

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 47682Post seanandruby

???
sean

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 47697Post lutonlagerlout

when we do steps /ramps for the local council if we exceed the 150mm below dpc we have to install code 4 lead to maintain the 150 rule,and an aco type drain
TBH it looks cat and as the men have said ,just angle away lightly and dpc vertically behind the step works just fine
LLL :)
"what,you want paying today??"