Need to determine sewer depth in my back garden - Sewer depth
-
- Posts: 12
- Joined: Tue Dec 29, 2009 6:42 pm
- Location: Tooting Broadway, London
Hello all & Hope you all had a merry Christmas.
I am building a rear extension which has currently gone in for planning permission.
I have to submit to Thames water an application for build over agreement as the extension protrudes 3m from the rear wall while the sewer line is roughly 2m away in my rear garden running parallell to my street. See existing layout:
http://picasaweb.google.co.uk/lh....ectlink
I am advised that in my application to Thames water, i need to detail the depth of the sewer line and it's position and show the mitigations will be in place to prevent damage to their sewer e.g. lintel.
I have obtained an asset search from Property Insight but it unfortunately doesn't give the depth of the sewer line, only the depth of manholes presumably in the main street? .. I have scanned an uploaded here (my house is 76 Eswyn Road) :
http://picasaweb.google.co.uk/lh....ectlink
http://picasaweb.google.co.uk/lh....ectlink
http://picasaweb.google.co.uk/lh....ectlink
I have consulted a local plumber who says that the sewer in my area is 10 ft deep. What confuses me is that the invert level in my inspection chamber is only around 800mm which means that the sewer line must drop 6 feet in the space of 3 feet! (I am told it is not normal for levels to change so drastically over small distances). See existing layout for position of inspection chamber relative to sewer line.
http://picasaweb.google.co.uk/lh....ectlink
I have done alot of reading on the matter and recall reading that the sewer level is more or less the same as the invert level in the inspection chamber.
This may be obvious to someone, if so, I would greatly appreciate advice.
Cheers.
I am building a rear extension which has currently gone in for planning permission.
I have to submit to Thames water an application for build over agreement as the extension protrudes 3m from the rear wall while the sewer line is roughly 2m away in my rear garden running parallell to my street. See existing layout:
http://picasaweb.google.co.uk/lh....ectlink
I am advised that in my application to Thames water, i need to detail the depth of the sewer line and it's position and show the mitigations will be in place to prevent damage to their sewer e.g. lintel.
I have obtained an asset search from Property Insight but it unfortunately doesn't give the depth of the sewer line, only the depth of manholes presumably in the main street? .. I have scanned an uploaded here (my house is 76 Eswyn Road) :
http://picasaweb.google.co.uk/lh....ectlink
http://picasaweb.google.co.uk/lh....ectlink
http://picasaweb.google.co.uk/lh....ectlink
I have consulted a local plumber who says that the sewer in my area is 10 ft deep. What confuses me is that the invert level in my inspection chamber is only around 800mm which means that the sewer line must drop 6 feet in the space of 3 feet! (I am told it is not normal for levels to change so drastically over small distances). See existing layout for position of inspection chamber relative to sewer line.
http://picasaweb.google.co.uk/lh....ectlink
I have done alot of reading on the matter and recall reading that the sewer level is more or less the same as the invert level in the inspection chamber.
This may be obvious to someone, if so, I would greatly appreciate advice.
Cheers.
-
- Site Admin
- Posts: 4732
- Joined: Fri Jul 28, 2006 8:47 pm
- Location: Somerset
- Contact:
Dig down and expose sewer? Then there it is in black and white, no guessing or assuming.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset
See what we get up to Our Facebook page
See what we get up to Our Facebook page
-
- Posts: 12
- Joined: Tue Dec 29, 2009 6:42 pm
- Location: Tooting Broadway, London
thanks, I was going to, but when the local tradesman suggested it was 10 feet down, the prospect of doing that was quickly un-appealing..
Was hoping that there were obvious tell-tale signs. For example by reading the map that insight sent back, i am at the start of the sewer line, which suggests that it shouldn't be too deep... ?
My objective at the mo is to get a good enough picture to submit an application to thames water. When the contractors break ground it *should* become clear.
Was hoping that there were obvious tell-tale signs. For example by reading the map that insight sent back, i am at the start of the sewer line, which suggests that it shouldn't be too deep... ?
My objective at the mo is to get a good enough picture to submit an application to thames water. When the contractors break ground it *should* become clear.
-
- Posts: 1136
- Joined: Sun May 08, 2005 9:25 am
- Location: North West
Put that shovel away kevin.
This is standard practice for planning permission with many of the water companies requiring proof of depth and the distance of the sewer from your property.
Any decent drainage contractor will have a sonar drain tracer which the send into the sewer, it sends a signal up to ground level showing the line of the drain and the depth.
It just depends on the size of the sewer and the distance from the nearest manhole which method they use to get the tracer into the sewer.
HTH
This is standard practice for planning permission with many of the water companies requiring proof of depth and the distance of the sewer from your property.
Any decent drainage contractor will have a sonar drain tracer which the send into the sewer, it sends a signal up to ground level showing the line of the drain and the depth.
It just depends on the size of the sewer and the distance from the nearest manhole which method they use to get the tracer into the sewer.
HTH
-
- Posts: 1136
- Joined: Sun May 08, 2005 9:25 am
- Location: North West
There`s no need for that kind of language, using the `D` word on the forum.
I will PM you a couple of London contractors i know, they will need to know the distance from the nearest inspection chamber on the sewer run, if its in a highway or not and roughly the sewer size.
If its not a great distance they can push the equipment in place, if not they may have to use a crawler system camera to piggy back the sonar into place.
I will PM you a couple of London contractors i know, they will need to know the distance from the nearest inspection chamber on the sewer run, if its in a highway or not and roughly the sewer size.
If its not a great distance they can push the equipment in place, if not they may have to use a crawler system camera to piggy back the sonar into place.
-
- Posts: 1136
- Joined: Sun May 08, 2005 9:25 am
- Location: North West
-
- Site Admin
- Posts: 4713
- Joined: Mon Jun 26, 2006 11:01 am
- Location: eastbourne
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
-
- Posts: 1136
- Joined: Sun May 08, 2005 9:25 am
- Location: North West
LLL
You will recall i put a post up last month regarding the water companies taking over all shared drainage from April 2011, this means that all shared drainage will be a public sewer.
Can you imagine the grief this will inflict on homeowners and builders trying to put up the simplest of extensions, not to mention the added cost of investigating/locating the sewer and implementing the exagerated design recommended for the foundations.
Stealth Tax !!!!! Sign the petition peeps if you havn`t already
You will recall i put a post up last month regarding the water companies taking over all shared drainage from April 2011, this means that all shared drainage will be a public sewer.
Can you imagine the grief this will inflict on homeowners and builders trying to put up the simplest of extensions, not to mention the added cost of investigating/locating the sewer and implementing the exagerated design recommended for the foundations.
Stealth Tax !!!!! Sign the petition peeps if you havn`t already
-
- Posts: 12
- Joined: Tue Dec 29, 2009 6:42 pm
- Location: Tooting Broadway, London
seanandruby wrote:Are you sure it is'nt a back drop into the manhole? There will be your pipe into the channel , then up the wall of the manhole there will be another pipe coming in ( might be bunged, or unbunged ) to allow maintenance on the pipeline.
amazing that you should say that. See picture of the inspection chamber.
http://picasaweb.google.co.uk/lh....ectlink
WHat does this mean? What is a backdrop into the manhole? I'm not too savvy with drainage, find myself learning a little more everytime.
just called the drainage contractors that Dave supplied, unfortunately one's not back till the new year and the other doesn't have the kit to do it. He advised to just use the invert level of the chamber...
-
- Posts: 1136
- Joined: Sun May 08, 2005 9:25 am
- Location: North West
Kevin
That is an interceptor trap on the outlet of the chamber, the pipework could then pass through a dropshaft before connecting into the sewer.
A drain camera inspection would tell you if the sewer is roughly the same depth as your manhole invert, if it does pass through a drop shaft its an easy enough job to calculate the depth of the sewer by the amount of camera rod you have pushed into the system from the manhole.
That is an interceptor trap on the outlet of the chamber, the pipework could then pass through a dropshaft before connecting into the sewer.
A drain camera inspection would tell you if the sewer is roughly the same depth as your manhole invert, if it does pass through a drop shaft its an easy enough job to calculate the depth of the sewer by the amount of camera rod you have pushed into the system from the manhole.
-