rayb
Posts: 4
Joined: Mon Nov 09, 2009 12:49 pm
Location: Edinburgh

Post: # 42997Post rayb

At the end of my drive I have an inspection chamber placed around 1988 and probably 1.5 meters deep. Made up of concrete sections. The chamber is sealed from the sewage system by screw cover. Was planning new manhole cover but found chamber half full water. Emptied but two weeks later half full again. Not sewage since screw cover not leaking. Water flowing into chamber through joins in concrete sections.

Can anyone advise - do I need to do anything or leave well alone?
rayb

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 43002Post lutonlagerlout

is this a foul ic or a rainwater ic?
i know in some parts of luton they have rainwater systems that go to big sump pits (sic) but if its clay these can flood
why do you need to change things?
a picture would be handy
regards LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 43009Post seanandruby

Is there a channel, or just a pipe in and a pipe out with about 300 ml below inverts. Sounds like it could be a catch pit if the latter. If that is the case then it will have water in it. The idea is to catch silt etc; which sinks to the bottom and allows the water to flow clean. Are sections raised to form an intended gap? If so could be a soakaway.
sean

DNgroundworks
Posts: 1951
Joined: Sat Dec 06, 2008 10:28 pm
Location: Preston, Lancashire

Post: # 43010Post DNgroundworks

I thought catch pit if it were a rainwater ic

rayb
Posts: 4
Joined: Mon Nov 09, 2009 12:49 pm
Location: Edinburgh

Post: # 43022Post rayb

Thanks for all the suggestions but it is a sewer inspection chamber and it used to be dry since I used it probably 15 years ago to free up a blockage. In Scotland all the inspection chambers for sewage have sealed access ports. The problem is that when I want to access the sewage system I have to bail out 18 inches water to access the system or get wet opening the access port. I was wondering if the chamber needed replacing (big job) or was there a way of sealing it to prevent ground water leaking in?
rayb

Tony McC
Site Admin
Posts: 8346
Joined: Mon Jul 05, 2004 7:27 pm
Location: Warrington, People's Republic of South Lancashire
Contact:

Post: # 43027Post Tony McC

Have I got this right? You have an IC through which runs a sealed sewer pipe which can be accessed via a screwed plate cover, so, in effect, the sewerage never makes contact with the IC itself.

In such an installation, it's possible that groundwater is penetrating the IC, as it may have been constructed as a SW IC rather than a foul IC, which would/should have sealed joints to prevent egress of sewage out of the chamber in the case of surcharge within the system.

There's no cheap fix. There are chamber lining products that would effectively seal the IC internally but they are a specialist installation requiring deep pockets. Occasionally, you can persuade an insurance company to fork out, but in most cases, they claim it is a pre-existing condition for which they have no liability.

If you can bale out the chamber, it may be possible to seal the joints from within using mastic, pitch or similar. Failing that, it may simply be a matter of re-building the chamber.
Site Agent - Pavingexpert

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 43137Post seanandruby

You may have whats known as a bristol trap. I can't believe we still put them in, but we do. They are a pain in the arse. Installed lots of them and also have broken loads out so that the sewage just flows. They are an old idea to stop gases, ie methane, escaping and rats climbing up the run. It will probably need jetwashing, that should cure it short term. Avoid flushing grease down the waste pipe as this builds up and causes its own problems. You can seal the joints with stop gap, fondue or sika mixed with neat cement. You have to use small amounts and be be quick with the mix as it goes off in about 40 seconds. its an unforgiving job that can take forever and means you have to be inside the manhole, not good as it is will come under confined space regulations. If the gaps are'nt letting silt in and not a lot of water, i would be inclined to leave it once you've got it flowing ok.
sean

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 43288Post seanandruby

Yes or no ???
sean

rayb
Posts: 4
Joined: Mon Nov 09, 2009 12:49 pm
Location: Edinburgh

Post: # 43301Post rayb

No it's an inspection chamber to access the sewage supply. The sewage line runs underneath the concrete base of the inspection chamber and access to the sewage is via an oval shaped section that is held in place by two screws. Effectively it is a rodding point to access the drain. The problem is that it fills up with rain water quite rapidly through the walls of the inspection chamber and consequently needs draining before access can be gained to the drain for rodding.

I have since found out that from manufacturers websites that now they are built with a drain to allow the rain water to run away.

Problem is that to add a drain requires I think a major excavation around the chamber. I cannot think of a way of adding a drain without having to dig through the concrete floor and risk rupturing the sewage line :(

Any other suggestions gladly received?
rayb

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 43306Post seanandruby

Ok now we are getting somewhere. What you have is a sealed inline chamber. Threw me because you would'nt normally have one outside, ( would normally be a traditional type with channel, slippers, benching etc; ) they are normally used inside buildings to stop gases etc emitting through. It's not a problem for the manhole to be half full of water most, if not all will have some water inside them.I install mainly this type of drainage ( must post some photos soon ) you would only remove the water if you had a problem with the line and therefore had to gain access.Then you would pump the water out. Don't worry about it until next time you have a blockage, then you can access it. As it is outside i would leave the plate raised up slightly so any water going in will drain away next time.
sean

rayb
Posts: 4
Joined: Mon Nov 09, 2009 12:49 pm
Location: Edinburgh

Post: # 43322Post rayb

In Scotland I think all the access chambers are built this way whether indoors or outside. The other problem is that the access plate has a rubber seal around the edge so even if I do not tighten the screws the water cannot drain away because of the downward pressure of the water. With all the rain recently I have left the trap off but am a bit worried that if I get a blockage downstream then the chamber will fill up with sewage.

However I think I will take your advise and simply let it fill up unless I need access. Many thanks
rayb

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 43323Post seanandruby

Yes it will have a gasket between plate and chamber. I use a couple of metal shims to lift it slightly, it don't need to be much, just a few mil. I had 60 manholes like that on my last contract, lots of pumping and over pumping. They had to be airtight for the air test, so had to empty them for cleaning, then benching, then drill steps and final cctv, was forever pumping :laugh:
sean

rab1
Posts: 1869
Joined: Sun Jun 07, 2009 10:19 pm
Location: scotland

Post: # 43327Post rab1

trust me sean knows about drains, if he tells you not to worry. dont :cool:
God loves a tryer