New drains on extension - How to fit

Foul and surface water, private drains and public sewers, land drains and soakaways, filter drains and any other ways of getting rid of water.
Post Reply
keithklj
Posts: 3
Joined: Tue Nov 18, 2008 1:28 am
Location: surrey

Post: # 32888Post keithklj

Hi i need help i have just built a new extension my dpc is quite low ie its about 12 inches above the the footing which naturally pretrudes from the wall by about 6 inches i need to put a drain in along this wall to take the waste from the kitchen my problem is all the traps are quite deep i need to keep it level with the path which will run down beside the building but as i need this path to be at least 6 inches below the dpc im a bit stuck do i have to come beyond the footing to drop the trap down or is there another way round it. hope this makes sense i will try to draw a picture and attach it tomorrow
THANKS
keith

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 32889Post seanandruby

yes pic would be nice. you can put the traps at any height with raising pieces. you may need slow bends to come up and over the founds.
sean

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 32895Post lutonlagerlout

you may have to kango a bit of the foundation to allow the gully to sit flush to the wall
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

keithklj
Posts: 3
Joined: Tue Nov 18, 2008 1:28 am
Location: surrey

Post: # 32902Post keithklj

Hi thanks for your replies wasnt sure if i was allowwed to cut a bit of the footing away. Ill attach some pics if someone tells me how to please
keith

Dave_L
Site Admin
Posts: 4732
Joined: Fri Jul 28, 2006 8:47 pm
Location: Somerset
Contact:

Post: # 32903Post Dave_L

Gunning the founds out on the edges to fit drainage will be fine as has been said - we've done it plenty of times when required.

Uploading pictures? This will help.

Photos
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset

See what we get up to Our Facebook page

keithklj
Posts: 3
Joined: Tue Nov 18, 2008 1:28 am
Location: surrey

Post: # 32904Post keithklj

thanks that helps i think when connecting into the exsisting ic do i have to break through as low down as poss? i will be going into another ic at the change of direction my exsisting ic is about 4 foot deep
that photo things sounds really complicated not sure i can get them up on here a bit beyond me :(
keith