Hi Flowjoe there is a 500mm dia access tube on top of the Klargester rain water tank,i need to build up around this to cover the opening and also provide an enclosed space next to the access tube for a valve and filter,i have two frames and covers to put end to end hence the 1300mm length i would require 36 blocks to build and bring up to ground level which although the tank has been back filled i`concerned about the weight. cheers Chunky.
-
- Site Admin
- Posts: 4713
- Joined: Mon Jun 26, 2006 11:01 am
- Location: eastbourne
-
- Posts: 1136
- Joined: Sun May 08, 2005 9:25 am
- Location: North West
There should be instructions with the tank on forming a reinforced base around the neck/tank but i am usually a bit wary of settlement on new installations.
You can buy an extension for the neck direct from the manufacturers but dependant on where the tank is sited i would use plastic chamber rings myself on a lightweight base, put two chambers side by side if needed. If they are to take vehicle weight then you will have to go belt and braces with it and install a solid reinforced base as sean said.
You can buy an extension for the neck direct from the manufacturers but dependant on where the tank is sited i would use plastic chamber rings myself on a lightweight base, put two chambers side by side if needed. If they are to take vehicle weight then you will have to go belt and braces with it and install a solid reinforced base as sean said.
-
- Site Admin
- Posts: 4713
- Joined: Mon Jun 26, 2006 11:01 am
- Location: eastbourne