Drainage - Surface water to main sewer

Foul and surface water, private drains and public sewers, land drains and soakaways, filter drains and any other ways of getting rid of water.
Post Reply
goldwheels
Posts: 7
Joined: Fri Apr 18, 2008 3:07 pm
Location: newbury

Post: # 27389Post goldwheels

HI THERE
I had a block drive installed 2 months ago,i have a land drainpipe of 9 mtrs in length running beneath it runs from a long drain at front of drive this was put in by paver, but it does not have a u trap.
Originaly i had a small square drain that had a u trap in it,the paver filled this in and cut into the top of the pipe further along and did not put a trap back,i did question him about this and i was told it would be ok as the drain laid back a little and it had a small amount of water in it.
Is it likely to have smells from it in hot weather.
Appreciate any views on this.
novice

Pablo
Posts: 1990
Joined: Sun Mar 25, 2007 10:49 pm
Location: N/Ireland

Post: # 27392Post Pablo

Potential alarmbells ringing could you elaborate is the landrain a perforated pipe and what diametre is the drianpipe installed by your paver. You need a u bend everytime as it the pipe will quickly block with sediment and debris and be a mare to clear. Give as much detail as you can as it's difficult to picture what you're talking about.
Can't see it from my house

Dave_L
Site Admin
Posts: 4732
Joined: Fri Jul 28, 2006 8:47 pm
Location: Somerset
Contact:

Post: # 27394Post Dave_L

If anything drains into a foul run/sewer, it will require a trap, full stop.

If it goes into a SW system, then it is *not always* required - but in the case of a combined system, it would be.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset

See what we get up to Our Facebook page

matt h
Posts: 607
Joined: Mon Jul 09, 2007 11:14 pm
Location: gosport

Post: # 27415Post matt h

agree with both above. If its a long run you should have some rodding facility as well:)
general builder, maintenance engineer, gas and plumbing installations, extensions etc

goldwheels
Posts: 7
Joined: Fri Apr 18, 2008 3:07 pm
Location: newbury

Post: # 27418Post goldwheels

Thanks for replys
iSorry got it wromg about being a land drain it is a solid 410mm pipe that runs directly into main house sewer drain this had a trap which as you say i used to clean debris from.
But the block paving contracor sealed the trap and installed plastic channel & grating line drainage(i think this is what you would call it) looks like a piece of guttering buried in the ground in front of driveway gates,then he cut into top of my original pipe to drain water from plastic channel without replacing u trap.
The reason he put in the plastic channel was the driveway has a fall to the gates from the pavement and we take a lot of water from this,hope this makes it clearer.
thanks again.
novice

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 27425Post lutonlagerlout

he should have installed a new trap, no question
and if he says the levels were wrong then he should have dug a soakaway
if its not trapped you have a good chance of getting blocked drains/rats/and smells

LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

goldwheels
Posts: 7
Joined: Fri Apr 18, 2008 3:07 pm
Location: newbury

Post: # 27428Post goldwheels

Hi
I have called the paver and he tells me he could not put a trap in because there was not enough room to put in a trap,i cant understand why as he raised my gates by about 4 inches as he had raised original drive level,he said he could put a foam yellow thing in to stop the leaves,but he did say he would come back and look at it.
thanks again.
novice

matt h
Posts: 607
Joined: Mon Jul 09, 2007 11:14 pm
Location: gosport

Post: # 27460Post matt h

You need a trap, and the contractor should have reconfigured your system to account for this. I can only assume he didnt want to pay for the trap and aco drain attachment .Best of luck and let us know how you get on:)
general builder, maintenance engineer, gas and plumbing installations, extensions etc

goldwheels
Posts: 7
Joined: Fri Apr 18, 2008 3:07 pm
Location: newbury

Post: # 27627Post goldwheels

hi matte h

still waiting for paver to come and sort out drain,i have looked into the linear drain and from bottom of gulley to top of pipe 4.5 inches,also noticed no 90 degree bend he just broke into top of old pipe with a sleeve resting on top.
(will keep you informed on his visit)
novice

James.Q
Posts: 368
Joined: Tue Sep 25, 2007 7:20 pm
Location: darwen
Contact:

Post: # 27634Post James.Q

make sure you have some oats and water for his horse when he calls :D
One of the symptoms of an approaching nervous breakdown is the belief that one's work is terribly important.

matt h
Posts: 607
Joined: Mon Jul 09, 2007 11:14 pm
Location: gosport

Post: # 27707Post matt h

YE HA!:D
general builder, maintenance engineer, gas and plumbing installations, extensions etc

Post Reply