I have two downpipes (one on left one on right) on the back of a garage. Each one will go into a bottle gully. I will then run a pipe below ground to connect each gully. From the gully on the left I will run another pipe to a brook.
Do surface water drains have to be roddable?
How deep should the pipe be that connects the two gullies?
Is this completely the wrong way to do this?!!!!
Please Help!!!!!!!!! :(
Thank You
Argh!! I wish I was a builder

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 21117Post seanandruby

yes they have to be rodable. go to the index and look under drainage.
sean

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 21124Post lutonlagerlout

why sean?
if they are going to a bottle gully,then any deitrius gets caught in the gully,and the water flows through
i would be tempted to put mesh or summat over the outlet to stop rats or such coming up the pipe
cheers LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

Mikey_C
Posts: 952
Joined: Mon Oct 30, 2006 8:24 pm
Location: Bournemouth, Dorset

Post: # 21126Post Mikey_C

Can't you just join them a bit futher down the line using Y connector, failing that have two straight runs into the brook. Either way the bottle gullies and the system should roddable, which most are now days.

Best of luck. :)

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 21132Post seanandruby

LLL the question was . . . . "do surface water drains have to be rod-able?" well yes they do. that's why we install bottle gullies, ic chambers etc; especially as he is discharging to a brook, with vermin using it as a nesting place in dry weather. also on large construction sites it is the norm to install an i c below and above ground. hope this answers your question. i am not in the habit of giving diyers the wrong info. the law is the law.
sean

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 21133Post lutonlagerlout

ahhh i see,thats why we use "roddable back inlet gullies"
on domestic stuff i have never seen an IC used on RW runs though
cheers LLL :)
"what,you want paying today??"

YOUR TEXT GOES HERE

Dave_L
Site Admin
Posts: 4732
Joined: Fri Jul 28, 2006 8:47 pm
Location: Somerset
Contact:

Post: # 21135Post Dave_L

I like using roddable bottle gullies - the ones with the removeable plug to allow rodding.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset

See what we get up to Our Facebook page

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 21143Post seanandruby

sorry for the confusion, i meant access chamber above ground. i will post some photos of a few rainwater i c chambers and manholes i have been working on and the need for them. i am also a great believer in a ball of chicken wire in the hopper of gullies.
sean

HayDown
Posts: 14
Joined: Tue Jul 24, 2007 2:25 pm
Location: Warwickshire

Post: # 21144Post HayDown

Thanks for all the info.
I could not understand why rain water drain had to be rodable, but the rat thing has answered my question.
Whats the minimum depth for PVC pipes?
Thank you
Argh!! I wish I was a builder

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 21148Post seanandruby

depending on what is going on top of it, IE, garden, patio, driveway etc: 600 to 900 to top of pipe. also if you are going into a brook you may have to build a header wall out of sand bags, or, similar to stop erosion of the bank. if you cant get the depth on the pipework you can go shallower if you surround in concrete. good luck
sean