New patio - Drains and manhole cover
-
- Posts: 10
- Joined: Mon May 29, 2006 1:23 pm
- Location: Hoghton, Lancashire
Hi,
Ive started work on patio that covers 13m wide by 4m deep in the main area. The patio will stretch the fill width of the rear of the house plus extend to a path around the conservatory which has been built on the side of the property.
I have two queries:
1. I'm planning to install a liner drain across the full width (13m) and I'm planning to install it 450mm from the rear house wall using a linear drain that has a built in fall. I've chosen 450mm as this allows me to neatly lay a full flag between the wall and the drain and doesn't place the drain in middle of the patio. The ground rises away form the house which has required me to dig out to a depth of 0.6 metre to attain the correct base level. I'm planning to build a retaining wall at this point.
Does this sound okay?
2. When digging out the main area I uncovered a large concrete inspection chamber. It would appear that the previous owner had knocked the brickwork off the top and just laid the metal grid on top of the concrete slab before burying the whole thing under a rockery. The problem I have is that I don't have much room to spare and I would like to fit one of those covers that allow a flag to be inserted directly onto the concrete slab.
Is this possible?
I do have photos if that helps but I'm unsure how to add them to this post.
Ive started work on patio that covers 13m wide by 4m deep in the main area. The patio will stretch the fill width of the rear of the house plus extend to a path around the conservatory which has been built on the side of the property.
I have two queries:
1. I'm planning to install a liner drain across the full width (13m) and I'm planning to install it 450mm from the rear house wall using a linear drain that has a built in fall. I've chosen 450mm as this allows me to neatly lay a full flag between the wall and the drain and doesn't place the drain in middle of the patio. The ground rises away form the house which has required me to dig out to a depth of 0.6 metre to attain the correct base level. I'm planning to build a retaining wall at this point.
Does this sound okay?
2. When digging out the main area I uncovered a large concrete inspection chamber. It would appear that the previous owner had knocked the brickwork off the top and just laid the metal grid on top of the concrete slab before burying the whole thing under a rockery. The problem I have is that I don't have much room to spare and I would like to fit one of those covers that allow a flag to be inserted directly onto the concrete slab.
Is this possible?
I do have photos if that helps but I'm unsure how to add them to this post.
Mark
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
-
- Posts: 10
- Joined: Mon May 29, 2006 1:23 pm
- Location: Hoghton, Lancashire
Thanks Tony,
Just one question, when you refer to 80mm I'm assuming that this is the height of the cover with flag inserted. Do these covers allow a flush fit onto the existing inspection cover or do I have to allow for a depth of cement for fixing purposes. As stated in my original post, I have very little height to play with and I don't want to have to reduce the height of the existing inspection cover. Not sure how I would do it anyway.
Just one question, when you refer to 80mm I'm assuming that this is the height of the cover with flag inserted. Do these covers allow a flush fit onto the existing inspection cover or do I have to allow for a depth of cement for fixing purposes. As stated in my original post, I have very little height to play with and I don't want to have to reduce the height of the existing inspection cover. Not sure how I would do it anyway.
Mark
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
-
- Posts: 10
- Joined: Mon May 29, 2006 1:23 pm
- Location: Hoghton, Lancashire
Hi Tony,
Sorry, I don't think I've explained the issue very well.
All that I have is a very large (approx 4-5ft dia.) flat concrete surface with a circular hole in the middle. This appears to be the top ring of a number of concrete rings which form a very deep inspection chamber. The chamber has internal steps and is approx 10ft deep. Any brick work or construction to house a standard manhole cover has been removed by the previouse occupant to allow them to hide the drain below the surface of the garden.
Many thanks for your time thus far.
Mark
Sorry, I don't think I've explained the issue very well.
All that I have is a very large (approx 4-5ft dia.) flat concrete surface with a circular hole in the middle. This appears to be the top ring of a number of concrete rings which form a very deep inspection chamber. The chamber has internal steps and is approx 10ft deep. Any brick work or construction to house a standard manhole cover has been removed by the previouse occupant to allow them to hide the drain below the surface of the garden.
Many thanks for your time thus far.
Mark
Mark
-
- Site Admin
- Posts: 4713
- Joined: Mon Jun 26, 2006 11:01 am
- Location: eastbourne
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
sounds like you have a land drain. i take it your house is fairly new?? the chances are that you have a machine dug land drain for stormwater,
you can get concrete covers with a manhole sized hole in the top of these ,but i feel reducing it would be best left to a professional as these covers are very heavy and difficult to manhandle with a machine
all the best tony
you can get concrete covers with a manhole sized hole in the top of these ,but i feel reducing it would be best left to a professional as these covers are very heavy and difficult to manhandle with a machine
all the best tony
-
- Posts: 10
- Joined: Mon May 29, 2006 1:23 pm
- Location: Hoghton, Lancashire
Hi Tony,
Thanks for the help thus far...
I've measured gap between the surface of the concrete cap and the DPC and it's 210mm. This leaves only 60mm to lay anything over the top without exceeding the planned patio level. I could add another 5-10 mm as the patio is draining towards the house into a linear drain set one slab away from the house.
Further info: The Concrete cap has a diameter of 147 cm and the access hole, which is set off-centre, has a diameter of 57.5 cm.
Just been to the Tobermore site at Leyland. They said that I may have to remove/replace one of the concrete rings in the chamber to reduce the height. Seemingly there are various depths of rings and I could swap an existing ring for a shallower version. This would then enable me to replace the missing brickwork etc. and still leave sufficient height to use hidden drain cover.
Regards
Mark
Thanks for the help thus far...
I've measured gap between the surface of the concrete cap and the DPC and it's 210mm. This leaves only 60mm to lay anything over the top without exceeding the planned patio level. I could add another 5-10 mm as the patio is draining towards the house into a linear drain set one slab away from the house.
Further info: The Concrete cap has a diameter of 147 cm and the access hole, which is set off-centre, has a diameter of 57.5 cm.
Just been to the Tobermore site at Leyland. They said that I may have to remove/replace one of the concrete rings in the chamber to reduce the height. Seemingly there are various depths of rings and I could swap an existing ring for a shallower version. This would then enable me to replace the missing brickwork etc. and still leave sufficient height to use hidden drain cover.
Regards
Mark
Mark
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
ye i gotcha now mark, yes the rings come in different sizes i think 100 mm is the smallest, but what i am saying is they are blooming heavy so watch your back!
that would be the answer remove 1 ring and replace with a smaller 1 then brick up to new level
alternatively put the out-laws down there and concrete over the lot (tongue firmly in cheek)
regards tony
that would be the answer remove 1 ring and replace with a smaller 1 then brick up to new level
alternatively put the out-laws down there and concrete over the lot (tongue firmly in cheek)
regards tony
-
- Site Admin
- Posts: 4713
- Joined: Mon Jun 26, 2006 11:01 am
- Location: eastbourne
-
- Posts: 22
- Joined: Mon Oct 31, 2005 7:37 pm
- Location: Scottish Highlands, Inverness
- Contact:
Hello Mark,
Sounds like your giving yourself too much work here, these recessed pavior covers can be anything from 47mm deep upwards, so why not just get a 47mm deep cover and bed it directly on top of the inspection chamber cover.
http://www.clark-drain.com/prod02.htm
The above will take you to a typical manufacturer, your local Builders merchant should be able to get you an alternative.
Sounds like your giving yourself too much work here, these recessed pavior covers can be anything from 47mm deep upwards, so why not just get a 47mm deep cover and bed it directly on top of the inspection chamber cover.
http://www.clark-drain.com/prod02.htm
The above will take you to a typical manufacturer, your local Builders merchant should be able to get you an alternative.
Ross Paving, Driveway and Patio specialists, www.Ross-Paving.co.uk
-
- Site Admin
- Posts: 15184
- Joined: Fri Aug 04, 2006 12:20 am
- Location: bedfordshire
i think you will find the 47 mm ones are double sealed covers intended for indoor use to cover a manhole ,we normally use these for floor screed.
i have never seen a insert cover for external use less than 65mm,also as the OP mentions he has a round hole so he needs some lintels/brickwork to get a square opening (or rectangular)
so he can bed the cover on.
a couple of years back i had an 18 ft storm drain dia.1800 under a drive that we were doing,it was a nightmare as the lid was only200mm below d.p.c so we had little to play with
better than soakaways though......
i have never seen a insert cover for external use less than 65mm,also as the OP mentions he has a round hole so he needs some lintels/brickwork to get a square opening (or rectangular)
so he can bed the cover on.
a couple of years back i had an 18 ft storm drain dia.1800 under a drive that we were doing,it was a nightmare as the lid was only200mm below d.p.c so we had little to play with
better than soakaways though......
-