Slot drainage on patio - Slot drainage on patio
-
- Posts: 11
- Joined: Mon Mar 26, 2018 6:46 pm
- Location: UK, North West
Hi,
I'm putting some slot drainage channel at the edge of my patio before laying the flags. I have a run of about 6 of them before then a p trap and then a length of pipe into some existing drainage. I am a bit concerned that the p trap will be entirely underground and I'll have no access to unblock the drain at any point, it there any issue with this or is there something I should do to allow access?
Thanks,
Dan
I'm putting some slot drainage channel at the edge of my patio before laying the flags. I have a run of about 6 of them before then a p trap and then a length of pipe into some existing drainage. I am a bit concerned that the p trap will be entirely underground and I'll have no access to unblock the drain at any point, it there any issue with this or is there something I should do to allow access?
Thanks,
Dan
-
- Site Admin
- Posts: 8346
- Joined: Mon Jul 05, 2004 7:27 pm
- Location: Warrington, People's Republic of South Lancashire
- Contact:
The P-trap sits directly beneath the slot drain, so you could use a compatible slot drain access cover to give you that access to the outlet and, thereby, the surface side of the P-trap.
Then, if you make the pipework from the P-trap conncet to the existing drainage line via an access cover or inspection chamber, you have access *back* to the P-trap from the sewer side.
Does that make sense?
Then, if you make the pipework from the P-trap conncet to the existing drainage line via an access cover or inspection chamber, you have access *back* to the P-trap from the sewer side.
Does that make sense?
Site Agent - Pavingexpert
-
- Posts: 11
- Joined: Mon Mar 26, 2018 6:46 pm
- Location: UK, North West
Thanks, that makes sense, but I dont think there is a slot drain access cover for the Bielbet Slot Drain: http://www.drainageshop.co.uk/category-6110.html
-
- Site Admin
- Posts: 8346
- Joined: Mon Jul 05, 2004 7:27 pm
- Location: Warrington, People's Republic of South Lancashire
- Contact:
I'm not familiar with that range, but I wouldn't be installing *any* linear system to whiuch I had no access for necessary maintenance. How do they expect you to clear out silt and detritus if there is no access section?
At least when you use 'standard' channel drainage, you can lift off the gratings to get access, but that's simply not practical with slot drainage systems, which is why access sections are absolutely essential.
At least when you use 'standard' channel drainage, you can lift off the gratings to get access, but that's simply not practical with slot drainage systems, which is why access sections are absolutely essential.
Site Agent - Pavingexpert
-
- Site Admin
- Posts: 4713
- Joined: Mon Jun 26, 2006 11:01 am
- Location: eastbourne
-
- Site Admin
- Posts: 4713
- Joined: Mon Jun 26, 2006 11:01 am
- Location: eastbourne