110volt tools have i messed up ?

For the discussion of hand tools, power tools, operated and non-operated plant, and all sorts of kit associated with the paving and drainage trades
dig dug dan
Posts: 2504
Joined: Thu Jul 10, 2003 10:20 pm
Location: hemel hempstead,herts. 01442 212315

Post: # 108087Post dig dug dan

seanandruby wrote:Yes it does plug on and then it is stepped down to 110 v a far safer power. You may of notices that the leads on transformer are not very long that is to keep it inside out of danger. As Cookie said IF you were going to use 240 outside then a RCD is needed. They need to be checked daily. There is an argument about cordless being used on sites but it is frowned upon. On large sites all electric tools are PAT tested every few months. An easy test you can do DDD is have a 110 cable and a230 cable plugged in then with bare hands cut into the 230v first, then cut into thev110 :laugh:
Good idea. Now wheres me stanley knife..... :laugh:
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 108088Post lutonlagerlout

since I started we have always used 110v stuff,pain lugging the transformer about,but its well ingrained now
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

cookiewales
Posts: 1270
Joined: Mon Aug 10, 2009 8:30 am
Location: york work anywhere where the stone takes me
Contact:

Post: # 108092Post cookiewales

lutonlagerlout wrote:since I started we have always used 110v stuff,pain lugging the transformer about,but its well ingrained now
LLL
And safer plus 110 tools last longer than 240
Originalstonepaving.com

The very best in natural stone paving in new and reclaimed materials
M: 07968 582231

lutonlagerlout
Site Admin
Posts: 15184
Joined: Fri Aug 04, 2006 12:20 am
Location: bedfordshire

Post: # 108653Post lutonlagerlout

had the CITB out yesterday signing up our new apprentice who is getting on great
one of the big questions was 230 or 110volt power tools
we are not allowed to have him on site unless we use 110volt end of,its a safety issue
LLL
"what,you want paying today??"

YOUR TEXT GOES HERE

lemoncurd1702
Posts: 712
Joined: Sat Oct 19, 2013 7:56 am
Location: South Wales
Contact:

Post: # 108654Post lemoncurd1702

Most of the world is running on 110v why are we on 230v, can't be a power issue if these tools run fine on 110v.
Must be one of these historical things like driving on the left.

The major issue for me though is the power surge the box creates when switching on sometimes trips the rcd, mostly houses with modern consumer units, far to sensitive some rcds.
My 5kv box trips every time :angry:
Cheers
Lemoncurd

GB_Groundworks
Site Admin
Posts: 4420
Joined: Sat Aug 09, 2008 3:55 pm
Location: high peak
Contact:

Post: # 108655Post GB_Groundworks

You cut through a 110v cable you've got two cores carrying 55v do you cut through one core you get a 55v shock you cut through 240v your getting a 110v shock from a single core enough to kill you. Plus 110v plugs are safer and better weather shielding

Battery chargers only thing we need 240v for have got inverter for van but not wired it in yet
Giles

Groundworks and Equestrian specialists, prestige new builds and sports pitches. High Peak, Cheshire, South Yorkshire area.

http://www.gbgroundworks.com

Forestboy1978
Posts: 1000
Joined: Sun Oct 23, 2011 9:57 am
Location: southampton, hampshire

Post: # 108658Post Forestboy1978

I've had a 230v shock and I'm still here.

Apparently it's good for the heart ;-)

dig dug dan
Posts: 2504
Joined: Thu Jul 10, 2003 10:20 pm
Location: hemel hempstead,herts. 01442 212315

Post: # 108659Post dig dug dan

Cut through any cable and surely it trips the rcd? Why wouldnt it?
Dan the Crusher Man
01442 212315
www.crusherhire.co.uk
"a satisfied customer? we should have them stuffed!"