Shared drain problem

Foul and surface water, private drains and public sewers, land drains and soakaways, filter drains and any other ways of getting rid of water.
Post Reply
n0chex
Posts: 119
Joined: Wed Apr 29, 2009 11:59 pm
Location: st helens

Post: # 107387Post n0chex

Hi all again, just a quick question in regards to a shared drain. My dad is on a shared drian with 3 other houses and he is last in line and when it rain hard his property mainly the garage gets flooded as the water lifts up the manhole cover in his yard and it also lifts the water covers up from the roof water.

This happens mostly when there is heavy rain and my main question is would all the houses be liable for his problem as in run a larger pipe going from his property to the main drain/sewer in the road as it only looks like a 75mm- 100mm pipe at the moment and to move all the water I would think it needs double this.

The united Utilities water inspector has been out last week and because it was not blocked they told my dad that they could not do anything.

He is a bot stuck now what to do and I have recommended he goes to the Local council and see the environmental health inspector as human waste comes into his property and garage when it happens.

Image

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 107388Post seanandruby

Is it a combination sewer, surface water and foul?
How old is the property? Is there an inspection chamber between your property and the manhole as lateral drains should have an IC minimum i metre in inside your boundary. 75 ml pipe with so much going onto it is a definite no no, should be 100ml at least , 150 if serving more than 10 dwellings. Need more info really ie inspection chambers, any soakaways, catchpits etc: with your drawing there doesn't seem to be any provision for surcharging of the rain water drainage. Is the water in the man hole flowing, or backing up, or is it backing up between your property and manhole? Could be you might need to dig a soakaway if your sub soil drains well. Is it possible to post photo's?
sean

n0chex
Posts: 119
Joined: Wed Apr 29, 2009 11:59 pm
Location: st helens

Post: # 107392Post n0chex

Combined drain sewer and surface water.
Inspection chambers x2 on my dads property both lift up when it rains hard......so backing up.
Not possible for pictures yet as dad lives a bit away.
House was built in the 80's

I thought I would mention the other properties sharing the drains all have since had large extensions or converted into large dwellings 6 beds 4 toilets and was a farm shop before. This problem is ONLY since the refurbishment and extensions of all the other properties he never had any trouble before.

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 107393Post seanandruby

If built in the 80s you will/should have a foul run and seperate surface water runs and inspection chambers. It might go into a combined system via a lateral drain. It would seem that either your lateral drain is blocked, collapsed, or the manhole is blocked etc: sometimes if the existing is deep then it could be connected via back drop system, which if not done by a competant person could of failed, i doubt if it is that because building control should of inspected it before signing it off. As the backing up only started since the new works there could be debris layig in the pipework causing it.
It may be that a simple rodding could shift the blockage but i would call a drain clearing company and get your neighbours to share the cost. Drain clearing in deep manholes can be highly dangerous, so best to get the experts on it. Is your dads drainage adopted? The main drain outside your property should be adopted so should be the responsibility off the local authority.
sean

n0chex
Posts: 119
Joined: Wed Apr 29, 2009 11:59 pm
Location: st helens

Post: # 107405Post n0chex

Thanks for the reply and I am not a drain expert so don't understand all the lingo but I do know United Utilities has been out and checked the drains and none are blocked just too much water ending up at my dads end when it rains heavy.

I think the trouble is the new dwellings and large extensions more roof space equals lots more water trying to get down the same pipe .

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 107406Post seanandruby

How does your soil drain? You may have to install a soakaway. Your inspection chambers must be very shallow?
sean

n0chex
Posts: 119
Joined: Wed Apr 29, 2009 11:59 pm
Location: st helens

Post: # 107409Post n0chex

Not sure to be honest mate and installing a soakaway sounds very expensive.
If the pipe going from my dads house to the main drain was larger then this would solve the problem but not sure if it his sole responsibility or everyone on the shared drain.

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 107410Post seanandruby

Don't know the set up of your IC to the main manhole. I was assuming it goes into a main rd, so you would need street works set up and that can be very expensive. Without knowing more i can only suggest less intrusive options. If your ICS are shallow then the water is struggling at the IC outlet and although needed a pipe ugrade may not silll cope as good as a deeper chamber would, because no surcharge. You really need to let us know more like depths, chamber size ie 450 or is it a shalliw IC about 220 dia'? No doubt a larger pipe would help a great deal but as you stated new builds have addrd to the volume of water going down a " 75/100ml pipe run." That's why i suggested a soakaway or attenuation cell. You really need to take the pressure off the foul run before solids start coming up out of the IC.
look here
and here
sean

Edgar
Posts: 42
Joined: Tue Apr 06, 2010 7:56 am
Location: Surrey

Post: # 107415Post Edgar

I'm no expert on drains but I understood that foul drains (sewers) that serve more than one property are now - since 1st Oct 2011 - the responsibility of the water and sewerage company. If this really is the case then it seems to me that nearly all the drains in the diagram above are no longer the "Dad's House" holders responsibility. The only bits that now belong to the individual householders are those short stubs linking their house to the shared section. And Dad's bit is tiny. Am I correct?

see:-
http://www.ccwater.org.uk/wateris....ldrains

Edgar
Edgar

Dave_L
Site Admin
Posts: 4732
Joined: Fri Jul 28, 2006 8:47 pm
Location: Somerset
Contact:

Post: # 107447Post Dave_L

Well that's what I understood too.
RW Gale Ltd - Civils & Surfacing Contractors based in Somerset

See what we get up to Our Facebook page