Rain water drainage

Foul and surface water, private drains and public sewers, land drains and soakaways, filter drains and any other ways of getting rid of water.
Post Reply
alpha1
Posts: 5
Joined: Thu Feb 26, 2015 2:25 pm
Location: essex

Post: # 102930Post alpha1

I am getting to a point where i will need to add the downpipes and hoppers for the rainwater. In the photo below, the 2 RWP in red are existing, the other are new.

Image

http://i1306.photobucket.com/albums....4u0.jpg



This will be my first attempt at extending the rainwater run offs by tapping into exiting hoppers. Am i right that i can tap into existing hoppers?

I think the existing pipe is Clay so i would need a boss connection so i could join it to plastics.Image

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 102931Post seanandruby

I would take them into shallow inspection chambers if depth ( 600 max ) allows, or universal I C if deeper up to 1200. 4D960
sean

alpha1
Posts: 5
Joined: Thu Feb 26, 2015 2:25 pm
Location: essex

Post: # 102932Post alpha1

Many thanks for the reply.

Something like this?
Image

Why would i include an inspection chamber?
And where would i put it in regards to my picture i included in my first post. Sorry, this is my first home build and the drainage scares me!

thanks
n

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 102933Post seanandruby

volume of water and has to be rodable. it will hold a surcharge of water.
like this
sean

alpha1
Posts: 5
Joined: Thu Feb 26, 2015 2:25 pm
Location: essex

Post: # 102934Post alpha1

seanandruby wrote:volume of water and has to be rodable. it will hold a surcharge of water.
like this
Many thanks Sean.

So because we have 2 existing hoppers, do we include 2 inspection drains which exit into each of the 2 hoppers we already have?

Image

Or can i have just 1 inspection chamber but feeding the 3 new hoppers i need to install running back to one of the existing hoppers to run off to?

Image

I could be talking jibberish though.

Thanks sean for your help!

seanandruby
Site Admin
Posts: 4713
Joined: Mon Jun 26, 2006 11:01 am
Location: eastbourne

Post: # 102935Post seanandruby

Are they down pipes from roof guttering? You need to connect the existing DP into the new IC which in turn goes into your main run. I'm assuming it goes to a manhole SWMH ?
The cover on these sre dubject to 1.5 tonne loading if done correctly on a plinth. You can always upgrade cover and frame to a 5 or 12.5 tonne for heavier loading. be good to know which way the existing runs.
sean